GWFlowBaseBC - PLAXIS 2D Input objects documentation

GWFlowBaseBC

Groundwater flow base boundary condition feature of a line.
Property Long name Unit Description
Name Name - Name of the groundwater flow base boundary condition feature.
Comments Comments - Comments on the groundwater flow base boundary condition feature.
UserFeatures UserFeatures - UserFeatures of the groundwater flow base boundary condition.
Parent Parent - Name of the parent object of the groundwater flow base boundary condition.
Behaviour Behaviour -
Seepage
Allows groundwater flow through this boundary.
Closed
Prevents groundwater flow through this boundary.
Head
Prescribes a certain head in this boundary.
Inflow
Prescribes an inflow through this boundary.
Outflow
Prescribes an outflow through this boundary.
Infiltration
Prescribes an infiltration through this boundary.
Constant value from previous phase
The boundary condition is set to the same value as the previous phase.
Maintain function from previous phase
The boundary condition continues calculating with the same function as the previous phase.
Distribution Distribution -
Uniform
The distribution is set to uniform.
Vertical increment
The distribution increases or decreases along the vertical axis.
Horizontal increment
The distribution increases or decreases along the horizontal axis.
Start/end values
The distribution varies linearly according to the start and end values.
TimeDependency Time dependency -
Constant
The value is constant in time.
Time dependent
The value varies with time.
DischargeFunction Discharge function - Discharge function of the groundwater flow boundary condition.
HeadFunction Head function - Head function of the groundwater flow boundary condition.
Discharge Discharge Length3 Total discharge for the groundwater flow boundary condition.
HeadMinimum Head minimum Length The minimum head value when the groundwater flow boundary condition is set to infiltration.
HeadMaximum Head maximum Length The maximum head value when the groundwater flow boundary condition is set to infiltration.
Href Href Length Reference value of the groundwater head when the groundwater flow boundary condition is set to head.
Hinc Hinc Length/Length Increment value of groundwater head when the groundwater flow boundary condition is set to head.
Qinc qinc,x,y Length3/Time/Lenth Incremental discharge when the groundwater flow boundary condition is set to inflow or outflow with linear distribution.
Qref |qref| Length3/Time Absolute value of discharge when the groundwater flow boundary condition is set to inflow or outflow.
RefPos RefPos - Reference position where head is equal to zero when the groundwater flow boundary condition is set to inflow or outflow with start/end values.
q_start q_start Length3/Time Start discharge value when the groundwater flow boundary condition is set to inflow or outflow with start/end values.
q_end q_end Length3/Time End discharge value when the groundwater flow boundary condition is set to inflow or outflow with start/end values.
y_start y_start Length Start y coordinate for the boundary when the groundwater flow boundary condition is set to inflow or outflow with start/end values.
y_end y_end Length End y coordinate for the boundary when the groundwater flow boundary condition is set to inflow or outflow with start/end values.
x_start x_start Length Start x coordinate for the boundary when the groundwater flow boundary condition is set to inflow or outflow with start/end values.
x_end x_end Length End x coordinate for the boundary when the groundwater flow boundary condition is set to inflow or outflow with start/end values.
h_start h_start Length Start head value for the boundary condition when the groundwater flow boundary condition is set to head with start/end values.
h_end h_end Length End head value for the boundary condition when the groundwater flow boundary condition is set to head with start/end values.